Related Experiment Video
Updated: May 19, 2026

Using MazeSuite and Functional Near Infrared Spectroscopy to Study Learning in Spatial Navigation
Published on: October 8, 2011
Highly-precise measurements of ambient oxygen using near-infrared cavity-enhanced laser absorption spectrometry
1Los Gatos Research, Mountain View, California 94041-1529, United States. m.gupta@lgrinc.com
Abstract:
Highly precise measurements of ambient oxygen have been used to constrain the carbon budget, study photosynthesis, estimate marine productivity, and prescribe individual pollution events to their point of origin. These studies require analyzers that can measure ambient oxygen with ppm-level precision. In this work, we utilize near-infrared off-axis integrated cavity output spectroscopy (off-axis ICOS) to quantify ambient oxygen with a precision (1σ, 100s) of ±7 ppm. By periodically calibrating the instrument, the analyzer is capable of making oxygen measurements to better than ±1 ppm (1σ). The sensor is highly linear (R(2) > 0.9999) over a wide dynamic range (0-100% oxygen). The sensor was combined with a commercial CO(2)/CH(4)/H(2)O Analyzer, and used to make measurements of respiration and fossil fuel pollution events with oxidative ratios ranging from 1.15-1.60. Future improvements will increase the analyzer precision (1σ, 100s) to better than ±1.4 ppm, and decrease the periodic referencing interval to >1 h. By including an additional diode laser, the instrument can be extended to make simultaneous measurements of O(2), CO(2), and H(2)O to enable improved understanding of carbon dioxide production and loss.
More Related Videos
08:58Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Flame Photometry: Overview
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Flame Photometry: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.