Multicenter comparison study of current methods to measure 25-hydroxyvitamin D in serum
Marcel J W Janssen1, Jos P M Wielders, Corinne C Bekker
1Laboratory of Clinical Chemistry and Haematology, VieCuri Medical Center, Venlo, The Netherlands. marceljanssen@viecuri.nl
Objectives:
Measurement of serum 25-hydroxyvitamin D [25(OH)D] is generally considered to be a reliable indicator of vitamin D status. The recent increase in diversity of 25(OH)D assays prompted us to evaluate the performance of chromatographic methods (two in-house ID-LC-MS/MS and HPLC (ClinRep, Recipe)), a protein binding method (Cobas-25(OH)D-total, Roche) and immunochemical methods (Liaison and RIA (Diasorin), iSYS (IDS), ADVIA Centaur (Siemens), and Architect i1000 and i2000 (Abbott)).
Methods:
Blood was drawn from randomly selected outpatients (N=60) at one site after informed consent. DEQAS and SRM 972 samples were obtained from the scheme organizer and NIST, respectively. Serum aliquots were prepared, frozen and transported to participating centers. Method comparison was performed according to CLSI-EP9 specifications.
Results:
With these patient samples, and in comparison with ID-LC-MS/MS, Deming regression parameters slope, intercept and R were found to be within the ranges [0.57-1.07], [-1.7 to 6.9 nmol/L] and [0.88-0.98], respectively. 25(OH)D2 in DEQAS and SRM samples was fully recognized by chromatographic methods, but only partially by protein binding and immunochemical methods. Chromatographic methods, and to a lesser extent the protein binding assay, showed cross-reactivity with 3-epi-25(OH)D3. Agreement of 25(OH)D assays to ID-LC-MS/MS in sorting patients into distinct 25(OH)D categories varied between 53% and 88%.
Conclusions:
Significant bias exists between ID-LC-MS/MS and many, but not all, other 25(OH)D assays. The variable response among different assays for 25(OH)D metabolites impedes the use of uniform cut-off values for defining vitamin D status. Our results indicate the need towards further standardizing assays for 25(OH)D measurement.
Related Concept Videos
Measurement of Bioavailability: Pharmacodynamic Methods
Measurement of Bioavailability: Pharmacokinetic Methods
Bioavailability Study Design: Single Versus Multiple Dose Studies
Bioavailability Study Design: Healthy Subjects Versus Patients
Therapeutic Drug Monitoring: Drug Analysis Methods
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...