The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
[Reintubation using the C-MAC videolaryngoscope. Implementation in patients with difficult airways initially managed
R Schalk1, C F Weber, C Byhahn
1Klinik für Anästhesiologie, Intensivmedizin und Schmerztherapie, Klinikum der J. W. Goethe-Universität, Theodor-Stern-Kai 7, 60590 Frankfurt a. M., Deutschland. richard.schalk@kgu.de
Background:
Securing the airway with supraglottic airway devices, such as a laryngeal tube, is a regular component of most difficult airway management algorithms. It is further recommended that in emergency medicine rescuers less skilled in endotracheal intubation should use supraglottic airways as a first line device. Exchanging the laryngeal tube with an endotracheal tube can be performed with video-assisted laryngoscopy as described below.
Material And Methods:
A total of 20 adult patients with airways managed using laryngeal tubes due to actual or anticipated difficult intubation underwent endotracheal intubation using the C-MAC videolaryngoscope. After deflating the cuffs of the laryngeal tube, seeking out the glottis was done by following the constructional landmarks of the laryngeal tube, considering concordance with anatomical landmarks of the human airway. In cases of failed video-assisted endotracheal intubation, the laryngeal tube that was still in situ was reinflated to re-establish ventilation of the lungs.
Results:
In 19 out of the 20 patients the laryngeal tube could be exchanged for an endotracheal tube with the video-assisted technique described. In one patient no laryngeal structures could be identified (Cormack and Lehane grade IV) even with the C-MAC videolaryngoscope and ventilation was continued via the laryngeal tube. No complications related to the video-assisted intubation technique were observed.
Conclusions:
The C-MAC videolaryngoscope is a mobile system which facilitates endotracheal intubation in patients with a difficult airway and a laryngeal tube in place. It is not only possible but recommended to leave the laryngeal tube in situ as a back-up when videolaryngoscopy fails.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Cardiopulmonary Resuscitation II: ACLS Airway Management