Related Experiment Video
Updated: May 19, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
A novel complete radiation protection system eliminates physician radiation exposure and leaded aprons
Peter Fattal1, James A Goldstein
1Michigan Cardiovascular Institute, Covenant Hospital, Saginaw, Michigan, USA.
Background:
Occupational health hazards associated with fluoroscopic-based procedures are well known, including a high prevalence of orthopedic problems, and those related to radiation exposure, particularly cancer and cataracts. This article reports the "first-in-man" clinical experience with a novel radiation protection system designed to eliminate radiation exposure to operators and thereby obviate the need for orthopedically burdensome leaded aprons. The Trinity Radiation Protection System consists of a combination of fixed shields, radiation drapes, and interconnecting flexible radiation resistant materials creating a complete radiation protection environment for the operators, yet maintaining full and unimpeded contact with the patient and total control of all operational elements of the catheterization equipment.
Methods And Results:
This report constitutes an analysis of 19 nonrandomized cases in which operator radiation exposure data were collected (Trinity Radiation Protection System n = 10 cases versus standard shielding alone n = 9). In all cases performed with the Trinity System, there was neither any measurable significant radiation exposure in any anatomic region nor for the total case, whereas operators performing cases with standard shielding were exposed to radiation in all regions of their bodies (total per case exposure differences P < 0.0001).
Conclusion:
The novel radiation protection system described is the first to provide a complete radiation barrier that eliminates radiation exposure to operators, thereby obviating the need for orthopedically burdensome leaded aprons. This approach to radiation protection has promise to enhance the safety and occupational health of medical personnel in the catheterization laboratory.
Related Concept Videos
Personal Protective Equipment
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Absorption of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiation: Applications
The average...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

