Related Experiment Video
Updated: May 19, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents
E Chatelut1, M L White-Koning, R Hj Mathijssen
1EA 4553 Institut Claudius-Regaud, Université de Toulouse, 20-24 rue du Pont St Pierre, 31052 Toulouse Cedex, France. chatelut.etienne@claudiusregaud.fr
Background:
Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patient's dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main advantages of dose banding are to reduce patient waiting time and improve pharmacy capacity planning; additional benefits include reduced medication errors, reduced drug wastage, and prospective quality control. This study compares dose banding with individual BSA dosing and fixed dose according to pharmacokinetic criteria.
Methods:
Three BSA bands were defined: BSA<1.7 m(2), 1.7 m(2)≤ BSA<1.9 m(2), BSA ≥ 1.9 m(2) and each patient dose was calculated based on a unique BSA-value per band (1.55, 1.80, and 2.05 m(2), respectively). By using individual clearance values of six drugs (cisplatin, docetaxel, paclitaxel, doxorubicin, irinotecan, and topotecan) from 1012 adult cancer patients in total, the AUCs corresponding to three dosing methods (BSA dosing, dose banding, and fixed dose) were compared with a target AUC for each drug.
Results:
For all six drugs, the per cent variation in individual dose obtained with dose banding compared with BSA dosing ranged between -14% and +22%, and distribution of AUC values was very similar with both dosing methods. In terms of reaching the target AUC, there was no significant difference in precision between dose banding and BSA dosing, except for paclitaxel (32.0% vs 30.7%, respectively; P<0.05). However, precision was significantly better for BSA dosing compared with fixed dose for four out of six drugs.
Conclusion:
For the studied drugs, implementation of dose banding should be considered as it entails no significant increase in interindividual plasma exposure.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Dosage Regimens: Designs and Approaches
Drug Dosing: Infants and Children
Dosage Regimen: Individualization
Dose Size and Dosing Frequency: Determination Methods
Drug Dosage Regimen: Overview
Typically, the starting dose and dosing interval are guided by the manufacturer's recommendations based on clinical trials conducted during and after drug...