Related Experiment Video
Updated: May 19, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study
Ulf Nyman1, Peter Björkdahl, Marie-Louise Olsson
1Department of Radiology, University of Lund, Lasarettet Trelleborg, Trelleborg, Sweden. ulf.nyman@skane.se
Background:
Mounting collective radiation doses from computed tomography (CT) implies an increased risk of radiation-induced cancer in exposed populations, especially in the young.
Purpose:
To evaluate radiation dose and image quality at 80-kVp CT to diagnose acute pulmonary embolism (PE) compared with a previous study at 100 and 120 kVp with all other scanning parameters unchanged.
Material And Methods:
A custom-made chest phantom with a 12 mg I/mL-syringe was scanned at 80/100/120 kVp to evaluate relative changes in computed tomographic dose index (CTDI(vol)), attenuation, image noise, and contrast-to-noise ratio (CNR). Fifty patients underwent 80 kVp 16-row detector CT at 100 "Quality reference" mAs. A total of 350 mg I/kg were injected to compensate for increased CNR at 80 kVp, while 300 mg I/kg had been used at 100/120 kVp. CTDI(vol), dose-length product (DLP), and estimated effective dose were evaluated including Monte Carlo simulations. Pulmonary artery attenuation and noise were measured and CNR calculated. Two radiologists evaluated subjective image quality using a four-grade scale.
Results:
Switching from 120 to 80 kVp in the phantom study decreased radiation dose by 67% while attenuation and noise increased 1.6 and 2.0 times, respectively, and CNR decreased by 16%. Switching from 120 to 80 kVp in the patient studies decreased estimated effective dose from 4.0 to 1.2 mSv (70% decrease) in median while pulmonary artery attenuation and noise roughly doubled from 332 to 653 HU and from 22 to 49 HU, respectively, resulting in similar CNR (13 vs. 12). At 80 kVp all examinations were regarded as adequate (8%) or excellent (92%).
Conclusion:
Switching from 120 to 80 kVp CT without increased mAs but slightly increased iodine dose may be of special benefit to diagnose PE in younger individuals with preserved renal function where the primary aim is to minimize radiation dose and reaching levels below that of scintigraphy.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...