Related Experiment Video
Updated: May 19, 2026

Development and Angiographic Use of the Rabbit VX2 Model for Liver Cancer
Published on: January 7, 2019
Comparison of semi-automatic volumetric VX2 hepatic tumor segmentation from cone beam CT and multi-detector CT with
Olivier Pellerin1, Mingde Lin, Nikhil Bhagat
1Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology, Johns Hopkins Hospital, Baltimore, MD 21287, USA.
Rationale And Objectives:
The purpose of this study was to compare tumor volume in a VX2 rabbit model as calculated using semiautomatic tumor segmentation from C-arm cone-beam computed tomography (CBCT) and multidetector computed tomography (MDCT) to the actual tumor volume.
Materials And Methods:
Twenty VX2 tumors in 20 adult male New Zealand rabbits (one tumor per rabbit) were imaged with CBCT (using an intra-arterial contrast medium injection) and MDCT (using an intravenous contrast injection). All tumor volumes were measured using semiautomatic three-dimensional volumetric segmentation software. The software uses a region-growing method using non-Euclidean radial basis functions. After imaging, the tumors were excised for pathologic volume measurement. The imaging-based tumor volume measurements were compared to the pathologic volumes using linear regression, with Pearson's test, and correlated using Bland-Altman analysis.
Results:
Average tumor volumes were 3.5 ± 1.6 cm(3) (range, 1.4-7.2 cm(3)) on pathology, 3.8 ± 1.6 cm(3) (range, 1.3-7.3 cm(3)) on CBCT, and 3.9 ± 1.6 (range, 1.8-7.5 cm(3)) on MDCT (P < .001). A strong correlation between volumes on pathology and CBCT and also with MDCT was observed (Pearson's correlation coefficient = 0.993 and 0.996, P < .001, for CBCT and MDCT, respectively). Bland-Altman analysis showed that MDCT tended to overestimate tumor volume, and there was stronger agreement for tumor volume between CBCT and pathology than with MDCT, possibly because of the intra-arterial contrast injection.
Conclusions:
Tumor volume as measured using semiautomatic tumor segmentation software showed a strong correlation with the "real volume" measured on pathology. The segmentation software on CBCT and MDCT can be a useful tool for volumetric hepatic tumor assessment.