Ultrafast vibrational dynamics of water at a charged interface revealed by two-dimensional heterodyne-detected

Prashant Chandra Singh1, Satoshi Nihonyanagi, Shoichi Yamaguchi

  • 1Molecular Spectroscopy Laboratory, RIKEN, 2-1 Hirosawa, Wako 351-0198, Japan.

Related Concept Videos

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration01:16

IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration

A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this process,...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...