Related Experiment Video
Updated: May 18, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Short implants with a nanometer-sized CaP surface provided with either a platform-switched or platform-matched
G Telleman1, H J A Meijer, A Vissink
1Department of Oral and Maxillofacial Surgery and Maxillofacial Prosthetics, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands; Department of Fixed and Removable Prosthodontics, Centre for Dentistry and Oral Hygiene, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands.
Objective:
To assess the performance of short nanorough implants (8.5 mm in length) provided with either a platform-matched or a platform-switched implant-abutment connection, placed in the resorbed posterior region of partially dentate patients.
Materials And Methods:
A total of 149 implants with a dual-acid surface and a discrete crystalline deposition of nanometer-sized CaP particles, with either a platform-matched (control) or a platform-switched implant-abutment connection (test) were placed (randomly assigned) in 92 patients. Follow-up visits were conducted 1 month and 1 year after placing the implant crown. Outcome measures were implant survival, radiographic peri-implant bone loss, clinical parameters, and patient's satisfaction.
Results:
One year after loading, 6 of 76 implants in the control group (survival 92.1%) and 3 of 73 implants in the test group (survival 95.9%) were lost (P = 0.33). Radiographic bone loss around test implants (0.50 ± 0.53 mm) was significantly less than around control implants (0.74 ± 0.61 mm; P < 0.005). With regard to implant survival, clinical parameters, and patient's satisfaction, no significant differences were observed between test and control group.
Conclusions:
For teeth replacements in the resorbed posterior region of partially dentate patients, short implants with a platform-switched implant-abutment connection showed significantly less peri-implant bone loss after 1 year in function, while implant survival, clinical parameters, and patient's satisfaction were independent of the implant-abutment connection design.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025