Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
A randomized trial to evaluate a launderable bed protection system for hospital beds
Edmond A Hooker1, Steven Allen, Larry Gray
1Department of Health Services Administration, Xavier University, 3800 Victory Parkway, ML 5141, Cincinnati, OH 45207-7331, USA. ehooker@mac.com.
Background:
Hospital beds are potential reservoirs of bacteria in hospitals. Preventing contamination of the bed and providing a cleaner surface should help prevent hospital-acquired infections (HAIs). Most hospital beds are cleaned between patients (terminal cleaning) using quaternary ammonia compounds (quats).
Objective:
The study had two objectives: identify levels of bacterial contamination on beds (including the mattress and bed deck) and evaluate a new launderable cover.
Methods:
Hospital beds on a bariatric surgery ward were randomized to either receive or not receive a launderable cover (Trinity Guardion, Batesville, IN). Bacterial counts on the surface of the mattress, the bed deck, and the launderable cover were then collected using Petrifilm™ Aerobic Count Plates (Petrifilm™, 3M™, St. Paul, MN, USA) (Petrifilm™) at three time periods (before patient use, after discharge, and after terminal cleaning). Standard hospital linen was used in all rooms.
Results:
The launderable cover (n = 28) was significantly cleaner prior to patient use than were the cleaned mattresses (n = 38) (1.1 CFU/30 cm2 vs. 7.7 CFU/30 cm2; p = 0.0189). The mattresses without launderable covers became significantly contaminated during use (7.7 CFU/30 cm2 on admission vs. 79.1 CFU/30 cm2 after discharge; p < 0.001). The mattresses with launderable covers did not become contaminated (3.0 CFU/30 cm2 on admission vs. 2.5 CFU/30 cm2 at discharge; p = 0.703). After terminal cleaning, the mattress surface contamination decreased to 12.8 CFU/30 cm2 (median 3 CFU/30 cm2; SD 7.8), but the bed deck was more contaminated (6.7 CFU/30 cm2 after discharge compared to 30.9 CFU/30 cm2 after terminal cleaning; p = 0.031).
Conclusions:
Terminal cleaning fails to eliminate bacteria from the surface of the hospital mattress. The launderable cover provides a cleaner surface than does terminal cleaning with quats, and the cover protects the bed from contamination during use.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Blinding
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Hand hygiene
Hand washing...