Assessment of the sensitivity of detecting drug-induced QTc changes using subject-specific rate correction
Raymundo Cassani González1, Elien B Engels, Bruno Dubé
1Hôpital du Sacré-Cœur de Montréal, Centre de Recherche, Montréal, QC, Canada.
Aims:
To quantify the sensitivity of QT heart-rate correction methods for detecting drug-induced QTc changes in thorough QT studies.
Methods:
Twenty-four-hour Holter ECGs were analyzed in 66 normal subjects during placebo and moxifloxacin delivery (single oral dose). QT and RR time series were extracted. Three QTc computation methods were used: (1) Fridericia's formula, (2) Fridericia's formula with hysteresis reduction, and (3) a subject-specific approach with transfer function-based hysteresis reduction and three-parameter non-linear fitting of the QT-RR relation. QTc distributions after placebo and moxifloxacin delivery were compared in sliding time windows using receiver operating characteristic (ROC) curves. The area under the ROC curve (AUC) served as a measure to quantify the ability of each method to detect moxifloxacin-induced QTc prolongation.
Results:
Moxifloxacin prolonged the QTc by 10.6 ± 6.6 ms at peak effect. The AUC was significantly larger after hysteresis reduction (0.87 ± 0.13 vs. 0.82 ± 0.12, p<0.01) at peak effect, indicating a better discriminating capability. Subject-specific correction further increased the AUC to 0.91 ± 0.11 (p<0.01 vs. Fridericia with hysteresis reduction). The performance of the subject-specific approach was the consequence of a substantially lower intra-subject QTc standard deviation (5.7 ± 1.1 ms vs. 8.8 ± 1.2 ms for Fridericia).
Conclusion:
The ROC curve provides a tool for quantitative comparison of QT heart rate correction methods in the context of detecting drug-induced QTc prolongation. Results support a broader use of subject-specific QT correction.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pharmacodynamic Models: Linear Concentration–Effect Model
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Therapeutic Drug Monitoring: Drug Analysis Methods
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant