Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A method of calculating the second dimension hold-up time for comprehensive two-dimensional gas chromatography
Imhoi Koo1, Yaping Zhao, Jun Zhang
1Department of Chemistry, University of Louisville, Louisville, KY 40292, USA.
Abstract:
A method of calculating the second dimension hold-up time for comprehensive two-dimensional gas chromatographic (GC×GC) data was developed by incorporating the temperature information of the second dimension column into the calculation model. The model was developed by investigating the relationship between the coefficients in each of six literature reported nonlinear models and the relationship between each coefficient and the second dimension column temperature. The most robust nonlinear function was selected and further used to construct the new model for calculation of the second dimension retention time, in which the coefficients that have significant correlation with the column temperature are replaced with expressions of column temperature. An advantage of the proposed equation is that eight parameters could explain the second dimension hold-up time as well as retention time corresponding to n-alkanes and column temperature in the entire chromatographic region, including the chromatographic region not bounded by the retention times of n-alkanes. To optimize the experimental design for collecting the isothermal data of n-alkanes to create the second dimension hold-up time model, the column temperature difference and the number of isothermal experiments should be considered simultaneously. It was concluded that a total of 5 or 6 isothermal experiments with temperature difference of 40 or 50 °C are enough to generate an accurate model. The test mean squared error (MSE) of those conditions ranges from 0.0428 to 0.0532 for calculation of the second dimension hold-up time for GC×GC data.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:502D-HPLC-MS Technology Combined with Molecular Network for the Identification of Components in Tibetan Medicine Aconitum pendulum
Published on: December 8, 2023
Related Concept Videos
Chromatographic Methods: Terminology
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...