Related Experiment Video
Updated: May 10, 2026

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Clampless off-pump versus conventional coronary artery revascularization: a propensity score analysis of 788 patients
Jochen Börgermann1, Kavous Hakim, André Renner
1Department of Cardiothoracic Surgery, Heart and Diabetes Center North-Rhine Westphalia, Ruhr-University Bochum, Georgstrasse 11, 32545 Bad Oeynhausen, Germany. jboergermann@hdz-nrw.de
Background:
This study aimed to assess if clampless off-pump coronary artery bypass grafting (CABG) decreases risk-adjusted mortality, stroke rate, and morbidity in unselected patients in comparison to conventional CABG.
Methods And Results:
Between July 2009 and November 2010, data of 1282 consecutive patients undergoing isolated CABG were prospectively recorded. In 30.8% (n=395), clampless off-pump revascularization was used, either with the PAS-Port automated central venous anastomosis system (n=310) or as total arterial revascularization without central anastomoses (n=85). Propensity score (PS) matching was performed based on 15 preoperative risk variables to correct for selection bias. In-hospital mortality and stroke rate as primary end point, as well as major complications and follow-up outcome of clampless off-pump (lessOPCAB) and conventional CABG (cCABG) were compared in 394 matched patient pairs (total: 788 patients). The clampless off-pump technique decreased the in-hospital rate of death (odds ratio, 0.25; 95% confidence interval, 0.05-1.18, P=0.080) and stroke (odds ratio, 0.36; 95% confidence interval, 0.13-0.99, P=0.048) significantly. Complications such as low cardiac output syndrome, prolonged ventilation and rethoracotomy were also reduced by lessOPCAB. Over a 2-year follow-up period overall survival, cerebrovascular and major adverse event rate were significantly lower in the lessOPCAB group, while the repeat revascularization rate was comparable.
Conclusions:
In a retrospective PS-matched analysis, clampless off-pump CABG lowers mortality, stroke rate and other morbidity in an unselected group of patients with coronary artery disease.