Related Experiment Video
Updated: May 18, 2026

Simultaneous Detection of Different Antibody Classes in a Multiplexed Serological Test
Published on: July 14, 2023
Characterizing antibody cross-reactivity for immunoaffinity purification of analytes prior to multiplexed liquid
Thomas J Laha1, Frederick G Strathmann, Zhican Wang
1Department of Laboratory Medicine, University of Washington, Seattle, WA 98195, USA.
Background:
Immunoassays for 1α,25-dihydroxyvitamin D [1α,25(OH)(2)D] lack analytical specificity. We characterized the cross-reactivity of an anti-1α,25(OH)(2)D antibody with purified vitamin D metabolites and used these data to map the chemical features of 1α,25(OH)(2)D that are important for antibody binding. Additionally, we hypothesized that when combined with isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS), antibody cross-reactivity could be used to semiselectively enrich for structurally similar metabolites of vitamin D in a multiplexed assay.
Methods:
Sample preparation consisted of immunoaffinity enrichment with a solid-phase anti-1α,25(OH)(2)D antibody and derivatization. Analytes were quantified with LC-MS/MS. Supplementation and recovery studies were performed for 11 vitamin D metabolites. We developed a method for simultaneously quantifying 25(OH)D(2), 25(OH)D(3), 24,25(OH)(2)D(3), 1α,25(OH)(2)D(2), and 1α,25(OH)(2)D(3) that included deuterated internal standards for each analyte.
Results:
The important chemical features of vitamin D metabolites for binding to the antibody were (a) native orientation of the hydroxyl group on carbon C3 in the A ring, (b) the lack of substitution at carbon C4 in the A ring, and (c) the overall polarity of the vitamin D metabolite. The multiplexed method had lower limits of quantification (20% CV) of 0.2 ng/mL, 1.0 ng/mL, 0.06 ng/mL, 3.4 pg/mL, and 2.8 pg/mL for 25(OH)D(2), 25(OH)D(3), 24,25(OH)(2)D(3), 1α,25(OH)(2)D(2), and 1α,25(OH)(2)D(3), respectively. Method comparisons to 3 other LC-MS/MS methods yielded an r(2) value >0.9, an intercept less than the lower limit of quantification, and a slope statistically indistinguishable from 1.0.
Conclusions:
LC-MS/MS can be used to characterize antibody cross-reactivity, a conclusion supported by our multiplexed assay for 5 vitamin D metabolites with immunoenrichment in a targeted metabolomic assay.
More Related Videos
09:08Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Published on: September 12, 2016
10:50Isolation of Labile Multi-protein Complexes by in vivo Controlled Cellular Cross-Linking and Immuno-magnetic Affinity Chromatography
Published on: March 9, 2010
Related Concept Videos
Affinity Chromatography
Cross-reactivity
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...