Related Experiment Video
Updated: May 18, 2026

Neuronavigation and Laparoscopy Guided Ventriculoperitoneal Shunt Insertion for the Treatment of Hydrocephalus
Published on: October 14, 2022
Endovascular intervention for repositioning the distal catheter of ventriculo-atrial shunt
Botao Xu1, Silky Chotai, Kaijun Yang
1Department of Neurosurgery, Southern Medical University, Nanfang Hospital, Guangzhou, China.
Insights
Distal ventriculo-atrial shunt catheter misplacement into the internal jugular vein can occur. Endovascular techniques successfully retrieved the misplaced shunt catheter in this case.
Area of Science:
- Neurosurgery
- Vascular Surgery
- Pediatric Surgery
Background:
- Distal ventriculo-atrial (VA) shunt displacement is a recognized complication.
- Misplacement into the internal jugular vein is a potential risk, particularly without intraoperative monitoring.
Purpose of the Study:
- To report a case of distal VA shunt catheter misplacement into the internal jugular vein.
- To highlight the utility of endovascular intervention for managing such complications.
Main Methods:
- A patient requiring a VA shunt due to ventriculo-peritoneal shunt failure underwent the procedure.
- Post-operative imaging revealed distal catheter misplacement in the left internal jugular vein.
- Endovascular retrieval of the misplaced catheter via the femoral vein was performed.
Main Results:
- The distal catheter of the VA shunt was successfully retrieved using endovascular techniques.
- This approach avoided the need for open surgical revision.
Conclusions:
- Misplacement of distal VA shunt catheters, including into the internal jugular vein, is a significant concern.
- Endovascular retrieval offers a minimally invasive and effective solution for managing misplaced VA shunt catheters.
Abstract:
Displacement of distal ventriculo-atrial (VA) shunt is not uncommon. However, misplacement of the distal catheter of VA shunt in the internal jugular vein is a possibility, especially when conducted without intraoperative monitoring. We describe a patient in whom a VA shunt was performed due to failure of ventriculo-peritoneal shunt and the distal catheter of the shunt was found to be misplaced in the left internal jugular vein. Endovascular intervention via femoral vein was used to retrieve the distal catheter.