Feng Pan1, Lianjun Pan, Aixia Zhang
1Department of Urology, Affiliated Drum Tower Hospital, Nanjing University, School of Medicine, Nanjing, China.
Objectives:
To compare the outcomes and complications of three methods of circumcision in a Chinese pediatric population.
Methods:
A total of 120 children were randomly assigned to three groups. Group I was submitted to circumcision using the Shenghuan disposable device according to Yan's method; group II was submitted to circumcision using the same device, but according to Peng's methods; group III was operated on by using the conventional scalpel/suture technique. The three groups were compared mainly by the following outcomes: duration of surgery, intraoperative bleeding, postoperative pain, cosmetic effect, and the rates of edema, dehiscence, scarring, adhesion and infection.
Results:
Groups I and II had less intraoperative bleeding. In terms of the duration of surgery, group I was the quickest. Pain scores in using the Shenghuan disposable device were higher at 6 h after surgery compared with the conventional scalpel/suture technique. The percentage of patients using paracetamol in group II was higher than that in group III at 12 h after surgery. Other complications were similar, and all three groups had successful outcomes.
Conclusions:
Circumcision using the Shenghuan disposable device represents a safer and time-saving option compared with the conventional scalpel/suture technique, with better cosmetic outcomes. Yan's method seems to be better than Peng's method when using the Shenghuan disposable device for circumcision in children.