Related Experiment Video
Updated: May 18, 2026

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Infrared thermographic comparison of temperature increases on the root surface during dowel space preparations using
Kerem Kilic1, Ozgur Er, Halil I Kilinc
1Department of Prosthodontics, Erciyes University, Faculty of Dentistry, Kayseri, Turkey. dtkeremkilic@hotmail.com
Purpose:
The purpose was to evaluate temperature increases during dowel space preparations with oval and circular fiber dowel systems.
Materials And Methods:
This study included 42 single-rooted human mandibular premolars. Roots were scanned with cone-beam computerized tomography (CBCT) to determine the ovoid root canal morphology. Root canals were treated with Ni-Ti rotary instruments and obturated. A second CBCT was taken to determine the thinnest dentin thickness of each root. Roots were randomly divided into two groups (n = 21) according to the fiber dowel system used: group 1, circular fiber dowel system (D.T. Light-Post); group 2, oval fiber dowel system (Ellipson Post). Dowel spaces were prepared using a circular fiber dowel drill and a diamond-coated ultrasonic tip with an oval section under water cooling until 9 mm dowel spaces were obtained. Temperature changes were recorded from the thinnest root surfaces using a FLIR E60 thermal imaging camera.
Results:
Temperature increases were significantly greater with the circular fiber dowel system than with the oval fiber dowel system (p < 0.05).
Conclusions:
Although both dowel systems generated high temperature increases on root surfaces, the relatively lower temperature increase associated with the use of oval fiber dowels in ovoid canals makes it preferable to the use of circular fiber dowels.
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Thin-Walled Hollow Shafts
Thermal Stress
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Thermal Strain
Masonry Cavity Walls
Maintaining a clean cavity during construction is...