Related Experiment Video
Updated: May 18, 2026

Methods for Quantitative Detection of Antibody-induced Complement Activation on Red Blood Cells
Published on: January 29, 2014
Autoimmune hemolytic anemia due to auto anti-N in a patient with sepsis
Lakhvinder Singh1, Sheetal Malhotra, Gagandeep Kaur
1Department of Transfusion Medicine, Government Medical College and Hospital, Chandigarh 160 032, India.
Abstract:
We describe a case of autoimmune hemolytic anemia (AIHA) due to anti-N in a young male patient with cellulitis. There have been several reports of anti-N in N positive individuals. But in all these reports, auto anti-N was mostly associated with underlying immunological conditions. We report here a case of auto anti-N in a patient of bacterial sepsis without any underlying immune disorder.
Related Concept Videos
Hypersensitivity Reactions: Cytolytic Reactions
Encephalitis l: Introduction
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target antigens A,...
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Nephrotic Syndrome I : Introduction
Rh Blood Group