Related Experiment Video
Updated: May 18, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Measurement of cardiac output during exercise in healthy, trained humans using lithium dilution and pulse contour
Adrian D Elliott1, Justin Skowno, Mahesh Prabhu
1School of Life Sciences, Kingston University, Surrey, UK. adrian.elliott@adelaide.edu.au
Abstract:
The aim of this study was to evaluate the use of pulse contour analysis calibrated with lithium dilution in a single device (LiDCO) for measurement of cardiac output (Q) during exercise in healthy volunteers. We sought to; (a) compare pulse contour analysis (PulseCO) and lithium indicator dilution (LiDCO) for the measurement of Q during exercise, and (b) assess the requirement for recalibration of PulseCO with LiDCO during exercise. Ten trained males performed multi-stage cycling exercise at intensities below and above ventilatory threshold before constant load maximal exercise to exhaustion. Uncalibrated PulseCO Q (Qraw) was compared to that calibrated with lithium dilution at baseline Qbaseline, during submaximal exercise below (Qlow) and above (Qhigh) ventilatory threshold, and at each exercise stage individually (Qexercise). There was a significant difference between Qbaseline and all other calibration methods during exercise, but not at rest. No significant differences were observed between other methods. Closest agreement with Qexercise was observed for Qhigh (bias ± limits of agreement: 4.8 ± 30.0%). The difference between Qexercise and both Qlow and Qraw was characterized by low bias (4-7%) and wide limits of agreement (> ± 40%). Calibration of pulse contour analysis with lithium dilution prior to exercise leads to a systematic overestimation of exercising cardiac output. A single calibration performed during exercise above the ventilatory threshold provided acceptable limits of agreement with an approach incorporating multiple calibrations throughout exercise. Pulse contour analysis may be used for Q measurement during exercise providing the system is calibrated during exercise.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...