Image quality of 320-detector row wide-volume computed tomography with diffuse lung diseases: comparison with
Osamu Honda1, Daisuke Takenaka, Mitsuru Matsuki
1Department of Radiology, Osaka University Graduate School of Medicine, Suita City, Osaka, Japan.
Objectives:
To evaluate image quality of 320-detector row wide-volume (WV) computed tomography (CT) compared to 64-detector row helical CT from axial images and coronal multiplanar reformation (MPR).
Methods:
Thirty-five patients with diffuse lung diseases were scanned using both 320-detector row WV CT (coneXact and volumeXact+) and 64-detector row helical protocols. Three blinded observers evaluated dislocation and heterogeneity of normal structures on 3 MPR patterns (WV scan with coneXact, WV scan with volumeXact+, and helical scan) using a 3-point scale from 1 (severe dislocation/heterogeneity) to 3 (no dislocation/heterogeneity). They also evaluated axial images of 2 scan patterns (WV with volumeXact+ and helical) using a 5-point scale from 1 (nondiagnostic) to 5 (excellent). Statistical analyses were performed with a post hoc test, Wilcoxon signed rank test, Mann-Whitney U test, or the Kendall W test.
Results:
The WV scans with the coneXact algorithm had significantly lower quality scores than the WV scans with the volumeXact+ algorithm and the helical scans (P < 0.01) with MPR. Helical scans had significantly lower quality scores than the WV scans with volumeXact+ for heterogeneity on the mediastinal window setting with MPR (P < 0.01). There were no significant differences concerning total image quality of axial images between the WV scans with the volumeXact+ algorithm and the helical scans.
Conclusions:
The overall image quality of WV scans with the volumeXact+ algorithm was almost comparable to that of the helical scans on the lung window setting, but density homogeneity with helical scans was inferior to that of the WV scans with the volumeXact+ algorithm on the mediastinal window setting with MPR.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET