Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
High temperature liquid chromatography-inductively coupled plasma mass spectrometry for the determination of
Amanda Terol1, Francisco Ardini, Marco Grotti
1Department of Analytical Chemistry, Nutrition and Food Science, University of Alicante, P.O. Box 99, 03080 Alicante, Spain. amanda.terol@ua.es
Abstract:
The potential of high temperature liquid chromatography (HTLC) with detection by inductively coupled plasma mass spectrometry (ICP-MS) for the determination of arsenosugars in marine organisms was examined for the first time. The retention behavior of four naturally occurring dimethylarsinoylribosides was studied on a graphite column using plain water as mobile phase. An aqueous solution of pH 8, ionic strength 13.8mM and containing 2% (v/v) of methanol, along with a column temperature of 120°C and a liquid flow rate of 1.0 mL/min, were selected as the optimal conditions, as they allowed the separation of the four arsenosugars in less than 18 min, without any interferences due to other common arsenic species (arsenite, arsenate, dimethylarsinate, methylarsonate and arsenobetaine). The run time could be further decreased to 12 min by working at 1.5 mL/min, although with a 3-4 times loss of sensitivity. The procedural limits of detection were 0.03-0.04 μg As/g dry mass, and the precision of the procedure ranged from 4% for arsenosugar glycerol to 18% for arsenosugar sulfate (RSD%, n=5). The developed method was applied to a number of representative biological samples, such as algae and crustaceans, providing results consistent with previous studies. In the red algae samples, the most of extracted arsenic was as arsenosugars (81-97%), mainly arsenosugar phosphate (56-94%). On the other hand, lower concentrations of these compounds were found in the crustacean, accounting for about 15% of the extracted arsenic.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors