Related Experiment Video
Updated: May 18, 2026

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Early angiographic evaluation after off-pump coronary artery bypass grafting
Jota Nakano1, Hitoshi Okabayashi, Hisashi Noma
1Department of Cardiovascular Surgery, Kokura Memorial Hospital, Kokura, Japan; Department of Cardiovascular Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Objectives:
One of the potential drawbacks of off-pump coronary artery bypass is reduced patency compared with conventional coronary artery bypass. This study examined the systematic angiographic evaluation after off-pump coronary artery bypass.
Methods:
Of the 1604 consecutive patients who underwent off-pump coronary artery bypass over 6 years, 1422 (89%) who underwent postoperative angiography were analyzed. Generalized estimating equations logistic analyses were used to investigate potential predictors of graft failure (FitzGibbon B or O).
Results:
Bilateral internal thoracic arteries were used in 78% of the patients. The mean number of distal anastomoses was 3.7 ± 1.2. The in-hospital mortality rate was 0.4%. Recipient coronary diameter less than 1.5 mm (odds ratio [OR], 1.62; 95% confidence interval [CI], 1.24-2.11) was an independent predictor of graft failure, whereas percent stenosis diameter greater than 75% (OR, 0.71; 95% CI, 0.53-0.93), sequential graft (OR, 0.69; 95% CI, 0.51-0.94), and left main disease (OR, 0.72; 95% CI, 0.53-0.96) were protective factors. In the subanalyses for each conduit, percent stenosis diameter was protective against left internal thoracic artery failure (OR, 0.61), whereas smaller recipient coronary diameter was associated with right gastroepiploic artery and saphenous vein graft failure (OR, 2.37 and 2.36, respectively). Left circumflex artery was associated with gastroepiploic artery graft failure, whereas sequential graft was again protective for the gastroepiploic artery (OR, 4.39 and 0.33, respectively).
Conclusions:
Smaller coronary diameter would be a predictor of graft failure, whereas percent stenosis diameter greater than 75%, sequential graft, and left main disease would be protective factors for off-pump bypass grafts.
More Related Videos
09:12Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery
Published on: March 27, 2018
05:25Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease V: Interprofessional Care