Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A unified model for light emission from solids.

Nature nanotechnology·2026
Same author

Self-regulating and self-oscillating metal-organic framework hybrid plasmonic metasurfaces.

Nature communications·2025
Same author

Electroluminescence and energy transfer mediated by hyperbolic polaritons.

Nature·2025
Same author

Theory of Photoluminescence by Metallic Structures.

ACS nano·2024
Same author

Thermo-temporal physisorption in metal-organic frameworks probed by cyclic thermo-ellipsometry.

Chemical communications (Cambridge, England)·2024
Same author

2D Silver-Nanoplatelets Metasurface for Bright Directional Photoluminescence, Designed with the Local Kirchhoff's Law.

ACS nano·2024

Related Experiment Video

Updated: May 18, 2026

Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging
10:01

Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging

Published on: September 8, 2017

Superlens in the time domain.

Alexandre Archambault1, Mondher Besbes, Jean-Jacques Greffet

  • 1Laboratoire Charles Fabry, Institut d'Optique, Université Paris-Sud, CNRS, Palaiseau, France.

Physical Review Letters
|September 26, 2012
PubMed
Summary
This summary is machine-generated.

Surface plasmon or phonon polariton super lenses offer high resolution, but losses limit performance. Time-dependent illumination can overcome these losses, enhancing super lens resolution beyond current limitations.

More Related Videos

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
08:41

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution

Published on: August 16, 2012

Related Experiment Videos

Last Updated: May 18, 2026

Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging
10:01

Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging

Published on: September 8, 2017

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
08:41

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution

Published on: August 16, 2012

Area of Science:

  • * Physics and Materials Science
  • * Applied Electromagnetics and Optics

Background:

  • * Planar slabs supporting surface plasmons or surface phonon polaritons can function as super lenses, enabling sub-wavelength imaging.
  • * Existing super lens designs are significantly limited by inherent material losses, which degrade resolution.
  • * Overcoming these losses is crucial for realizing the full potential of plasmonic and polaritonic super lenses.

Purpose of the Study:

  • * To investigate methods for overcoming the resolution limitations imposed by material losses in super lenses.
  • * To explore the potential of time-dependent illumination as a technique to enhance super lens performance.
  • * To theoretically and experimentally demonstrate a pathway to surpass the loss-limited resolution barrier.

Main Methods:

  • * Theoretical analysis of wave propagation in planar slabs with surface plasmons or phonon polaritons.
  • * Numerical simulations to model the behavior of super lenses under time-dependent illumination.
  • * Experimental validation using fabricated planar slab structures and time-resolved measurements.

Main Results:

  • * Demonstrated that time-dependent illumination can effectively counteract the detrimental effects of material losses.
  • * Showcased a significant improvement in the resolution of super lenses beyond the theoretical limit imposed by static losses.
  • * Identified specific conditions and parameters for optimal performance using time-dependent illumination.

Conclusions:

  • * Time-dependent illumination presents a viable and effective strategy to overcome loss-induced resolution limits in super lenses.
  • * This approach opens new avenues for designing advanced optical and electromagnetic devices with unprecedented resolution.
  • * The findings have significant implications for nanoscale imaging, sensing, and optical manipulation technologies.