Objectives:
The aim of this study was to describe and compare a simplified vertebral heart scale computation method (Objective VHS) with the original Buchanan method (Buchanan VHS).
Methods:
The Objective VHS was compared to the Buchanan VHS method in 42 dogs including 14 healthy dogs and 28 dogs with mitral insufficiency. For the Objective VHS, the sum of the length of the long and short axes of the cardiac silhouette obtained in centimetres using a metric ruler was subsequently converted into units of vertebral length by means of a direct standardization method. The Buchanan VHS was obtained as previously described.
Results:
No significant differences in vertebral heart scale values were found between the two methods in all dogs. There was a strong positive correlation (0·99) between Objective VHS and Buchanan VHS.
Clinical Significance:
The use of a direct standardization method based on a unit conversion allows -computation of vertebral heart scale values without transposing long and short axes to the cranial edge of T4.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...