Related Experiment Video
Updated: May 18, 2026

Assessment of Sensory Thresholds in Dogs Using Mechanical and Hot Thermal Quantitative Sensory Testing
Published on: October 26, 2021
Estimates of biological variation in routinely measured biochemical analytes in clinically healthy dogs
Craig G Ruaux1, Patrick C Carney, Jan S Suchodolski
1Department of Clinical Sciences, College of Veterinary Medicine, Oregon State University, Magruder Hall, 700 SW 30th Street, Corvallis, OR 97331, USA. craig.ruaux@oregonstate.edu
Background:
The degree of biological variation in routinely measured concentrations and activities of biochemical analytes has not been well defined in client-owned pet dogs.
Objectives:
The aim of this study was to define indices of biological variation and, where appropriate, indices of individuality and critical change values for routinely measured serum biochemical analytes in a group of clinically healthy dogs owned and housed privately.
Methods:
A prospective cohort study was conducted. Serum samples obtained from clinically healthy adult dogs at varying intervals over a 12-week period were analyzed. For each sample, a panel of 14 analytes was measured. Three levels of outlier analyses were applied (analytical, intra-individual, and inter-individual), followed by nested ANOVA to calculate intra-individual, inter-individual, and analytical coefficients of variation (CV(I), CV(G), and CV(A), respectively).
Results:
Specimens from 11 dogs were analyzed. Individuality indices ranged from 0.9 for glucose and total triglyceride concentrations to 3.4 for ALT activity. Analytical variation (CV(A) ) was > ½ CV(I) for 9/14 analytes, failing to meet criteria for acceptable analytical variation when defining critical change values. Where analyzer performance was acceptable, critical change values ranged from 26.4% for glucose concentration to 84.0% for total triglyceride concentration.
Conclusions:
Many frequently measured analytes included in routine serum biochemical panels have high individuality. Thus, use of standard reference intervals to monitor changes over time in an individual is likely to miss meaningful biological change.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Bioequivalence Data: Statistical Interpretation
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Measurement of Bioavailability: Pharmacodynamic Methods
Measurement of Bioavailability: Pharmacokinetic Methods
Bioavailability Study Design: Healthy Subjects Versus Patients