Refolding of urea-denatured α-chymotrypsin by protein-folding liquid chromatography

Ke Congyu1, Sun Wujuan, Zhang Qunzheng

  • 1College of Chemistry & Chemical Engineering, Xi' An ShiYou University, Xi'an, China.

Related Concept Videos

Molecular Chaperones and Protein Folding03:00

Molecular Chaperones and Protein Folding

The native conformation of a protein is formed by interactions between the side chains of its constituent amino acids. When the amino acids cannot form these interactions, the protein cannot fold by itself and needs chaperones. Notably, chaperones do not relay any additional information required for the folding of polypeptides; the native conformation of a protein is determined solely by its amino acid sequence. Chaperones catalyze protein folding without being a part of the folded protein.
The...
Protein Folding01:25

Protein Folding

Proteins are chains of amino acids linked together by peptide bonds. Upon synthesis, a protein folds into a three-dimensional conformation, critical to its biological function. Interactions between its constituent amino acids guide protein folding, and hence the protein structure is primarily dependent on its amino acid sequence.
Protein Structure Is Critical to Its Biological Function
Proteins perform a wide range of biological functions such as catalyzing chemical reactions, providing...
Protein Folding01:22

Protein Folding

Overview
Protein Folding01:22

Protein Folding

Overview
Protein Folding Quality Check in the RER01:29

Protein Folding Quality Check in the RER

ER is the primary site for the maturation and folding of soluble and transmembrane secretory proteins. The calnexin cycle is a specific chaperone system that folds and assesses the confirmation of N-glycosylated proteins before they can exit the ER lumen. The primary players of this quality check pipeline are the lectins, ER-resident chaperones, and a glucosyl transferase enzyme. In case the calnexin system in the lumen fails to salvage a misfolded protein, it is transported to the cytoplasm...
Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...