Related Experiment Video
Updated: May 18, 2026

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Venous filling time using air-plethysmography correlates highly with great saphenous vein reflux time using duplex
C R Lattimer1, M Azzam, E Kalodiki
1Ealing Hospital & Imperial College, London SW7 2AZ, UK.
Objectives:
Venous filling time (VFT90) is the time taken to reach 90% of the venous volume in the calf. It is recorded by air-plethysmography (APG(®)) and is assumed to measure global venous reflux duration. However, this has never been confirmed by duplex. The aim of the study was to compare VFT on APG to venous reflux time/duration (RT) measured simultaneously with duplex on the same patients.
Method:
Twenty-six consecutive patients, M:F = 16:10, age (25-78), C1 = 1, C2 = 4, C3 = 8, C4a = 6, C4b = 4, C5 = 2, C6 = 1, underwent simultaneous APG with duplex. The venous filling index (VFI, mL/second), VFT90 (seconds), great saphenous vein (GSV) RT on duplex, averaged thigh GSV diameter and thigh length (length) between the APG sensor air-cuff and duplex transducer were recorded. The VFT100 was calculated by VFT90/0.9. The additional time taken to fill the thigh was achieved using the VFI, length and deep vein diameter (d), to determine the corrected reflux duration: CRD = VFT100 + (length × πd(2)/4 (1/VFI)).
Results:
Twenty-five patients are presented. One patient with very mild reflux (VFT90 = 55.9 seconds) had an indeterminate endpoint on duplex and was excluded. The median (range) VFI and GSV diameter was 4.9(1.3-15.5) mL/second and 7(4-17) mm, respectively. The VFT90 and VFT100 both correlated with RT on duplex (Spearman, P < 0.0005) at: r = 0.933, r(2) linear = 0.72 and r = 0.933, r(2) linear = 0.68, respectively. The median (interquartile range) filling time with VFT90 was less than the duplex RT at 24 (16.9) versus 28 (20) seconds respectively, P < 0.0005 (Wilcoxon). The median percentage underestimation improved from 24% to 16% and then 4% using the VFT90, VFT100 and CRD, respectively.
Conclusions:
This is the first study to compare APG parameters with duplex by performing simultaneous measurements. There was an excellent correlation between the VFT90 versus duplex RT, thereby comparing reverse flow in a single superficial vein against the legs overall venous haemodynamic status. These tests can both be used in the quantification of reflux.
More Related Videos
09:04Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the knee,...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...