Related Experiment Video
Updated: May 18, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Detection of clenbuterol at trace levels in doping analysis using different gas chromatographic-mass spectrometric
Sheng Yang1, Xin Liu, Yanyi Xing
1National Anti-doping Laboratory, China Anti-Doping Agency, 1st Anding Road, ChaoYang District, Beijing 100029, P. R. China. yangsheng@chinada.cn
Abstract:
This study demonstrates the development of a gas chromatography-triple quadrupole tandem mass spectrometry (GC-MS-MS) assay to detect clenbuterol in human urine and the comparison of this method with GC-MS techniques and gas chromatography-high resolution mass spectrometry (GC-HRMS) techniques. Urine samples were hydrolyzed with β-glucuronidase, extracted with methyl tert-butyl ether and dried under nitrogen. The derivative reagent was N-methyl-N-(trimethylsilyl)-trifluoroacetamide with NH4I and was analyzed by GC-MS, GC-MS-MS and GC-HRMS. A validation study was conducted by GC-MS-MS. The analyses of clenbuterol using different mass spectrometric techniques were compared. The limit of detection (LOD) for clenbuterol in human urine was 2 ng/mL by GC-MS (selected ion monitoring mode: SIM mode), 0.06 ng/mL by GC-HRMS and 0.03 ng/mL by GC-MS-MS, respectively, while the LOD by GC-HRMS was 0.06. With GC-MS-MS, the intra-assay and inter-assay precisions were less than 15%, the recoveries were 86 to 112% and the linear range was 0.06 to 8.0 ng/mL. The GC-MS under SIM mode can be used as a screening tool to detect clenbuterol at trace levels in human urine. The GC-MS-MS and GC-HRMS methods can confirm clenbuterol when its concentration is below 2 ng/mL. The results demonstrate that the GC-MS-MS method is quite sensitive, specific and reliable for the detection of clenbuterol in doping analysis.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.