Magnetic resonance properties of Gd(III)-bound lipid-coated microbubbles and their cavitation fragments

Jameel A Feshitan1, Michael A Boss, Mark A Borden

  • 1Department of Mechanical Engineering, University of Colorado, Boulder, Colorado 80309, United States.

Insights

Gadolinium-labeled microbubbles show altered magnetic properties after fragmentation, depending on label location. This difference may enable MRI detection of microbubbles and their fragments for theranostics.

Area of Science:

  • Biomaterials Science
  • Medical Imaging
  • Nanotechnology

Background:

  • Gas-filled microbubbles are promising theranostic agents for MRI-guided focused ultrasound surgery (MRIgFUS).
  • Previous studies at 9.4 T MRI showed increased longitudinal relaxivity (r(1)) of gadolinium (Gd(III))-labeled microbubbles after fragmentation, attributed to lipid monolayer-to-bilayer transition.

Purpose of the Study:

  • To investigate the mechanism of relaxivity changes after microbubble fragmentation by comparing Gd(III) bound to lipid headgroups versus PEG brushes.
  • To assess the impact of microbubble fragmentation on both longitudinal (r(1)) and transverse (r(2)*) relaxivity at a clinically relevant MRI field strength (1.5 T).

Main Methods:

  • Synthesized Gd(III)-labeled microbubbles with labels at either the lipid headgroup or PEG brush regions.
  • Measured longitudinal (r(1)) and transverse (r(2)*) molar relaxivities using Nuclear Magnetic Resonance (NMR) at 1.5 T before and after microbubble fragmentation.
  • Analyzed the influence of the microbubble gas core on T(1) and T(2)* signals.

Main Results:

  • Lipid-headgroup-labeled microbubbles showed increased r(1) and unchanged r(2)* post-fragmentation.
  • PEG-labeled microbubbles exhibited decreased r(1) and r(2)* post-fragmentation.
  • The microbubble gas core enhanced T(2)* signal concentration-dependently but minimally affected T(1).

Conclusions:

  • Microbubble fragmentation alters MRI contrast properties differently based on Gd(III) labeling location.
  • NMR can measure biomembrane packing structure and differentiate microbubble fragments.
  • Two mechanisms, proton-exchange enhancement and gas/liquid interface magnetic inhomogeneity, can be exploited for MRI detection of microbubbles and their fragments.