Related Experiment Video
Updated: May 17, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Changes in N-terminal pro-brain natriuretic peptide correlate with fluid volume changes assessed by bioimpedance in
1UCL Centre for Nephrology, Royal Free Hospital, University College London Medical School, London, UK. andrewdavenport @ nhs.net
Background/Aims:
Both brain natriuretic peptide (BNP) and volume overload are reported to be powerful predictors of survival for peritoneal dialysis patients. The usefulness of single BNP determinations in helping determine volume status in peritoneal dialysis patients remains controversial, so we reviewed serial BNP and multifrequency bioimpedance measurements to determine whether changes in BNP reflected changes in volume status.
Methods:
Prospective measurements of fluid volume by multifrequency bioimpedance and serum N-terminal pro-BNP (NTproBNP) were conducted in stable adult peritoneal dialysis outpatients attending for routine assessments of peritoneal dialysis adequacy and transport status.
Results:
A total of 189 serial measurements were made in 92 patients, and NTproBNP increased from a median of 162.5 pmol/l (interquartile range 82-385.4) to 195 pmol/l (interquartile range 101.9-348.6; p < 0.05). Changes in NTproBNP correlated with changes in extracellular water (ECW), total body water (TBW) and ECW/TBW (r = 0.38, 0.31 and 0.45, respectively; all p < 0.0001). Patients were divided into quartiles depending upon NTproBNP changes; those with the greatest fall in NTproBNP had significant falls in ECW (p < 0.001), TBW (p = 0.001) and ECW/TBW (p < 0.001) compared to the quartile with the greatest increase in NTproBNP, who also had an increase in systolic blood pressure from 133.5 ± 22.7 to 142.7 ± 28.8 mm Hg (p = 0.0078), whereas it fell in the quartile with the greatest fall in NTproBNP (143.8 ± 24.6 vs. 136.5 ± 18.7 mm Hg).
Conclusions:
Serial measurements of NTproBNP correlated with changes in volume assessments made by multifrequency bioimpedance in peritoneal dialysis outpatients. As multifrequency bioimpedance measures total ECW, rather than effective plasma volume, serial NTproBNP determinations may prove an adjunct to the clinical assessment of volume status in peritoneal dialysis patients.
Related Concept Videos
Hormonal Regulation of Blood Pressure
Epinephrine and Norepinephrine
The adrenal medulla releases epinephrine and norepinephrine, catecholamines that enhance and extend the sympathetic or "fight or flight" physiological response. These hormones escalate heart rate and the force of contraction while...
Peritoneal Dialysis III: Nursing Management
Heart Failure II: Pathophysiology
Hemodialysis III: Nursing Management
Regulation of Water Intake
Heart Failure Drugs: Diuretics
