Related Experiment Video
Updated: May 17, 2026

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Arsenic remediation from drinking water using Fenton's reagent with slow sand filter
Dipali Jasudkar1, Rupali Rakhunde, Leena Deshpande
1Water Technology and Management Division, National Environmental Engineering Research Institute, CSIR-NEERI, Nagpur, 440020 Maharashtra, India. dipjasudkar@gmail.com
Abstract:
This paper describes the development of a remediation approach based on the pre-oxidation using Fenton's reagent and the subsequent removal of arsenic (As) through sand filtration from drinking water. The efficiency of the process was carried out including As(III) and As(V) with various concentration ratios up to 3,000 ppb. Efficient removal of As was observed within WHO guideline value of 10 ppb. The recoveries of samples were found to be 98 % ± 2.5 %. The process was applied to field samples, where results show considerable reduction in As concentrations. This process is cost effective for treatment of drinking water with high concentration of As.
Related Concept Videos
Acid Mine Drainage
Factors Affecting Solubility
Microbial Bioremediation of Uranium
Microbial Leaching
Precipitation and Co-precipitation
Filtration