SPME-based air sampling method for inhalation exposure assessment studies: case study on perchlorethylene exposure in dry cleaning
Related Experiment Video
Updated: May 17, 2026

An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
Mohammad Javad Zare Sakhvidi1, Abdul Rahman Bahrami, Alireza Ghiasvand
1Department of Occupational Health, Faculty of Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.
Abstract:
Exposure to perchlorethylene, especially for dry cleaning workers and for people living near dry cleaning shops, could lead to several diseases and disorders. This study examines the value of solid-phase microextraction (SPME) for sampling perchlorethylene in the atmosphere of dry cleaning shops. Carboxen/polydimethylsiloxane (CAR/PDMS) in 0.5-cm retracted mode was selected. There were no significant differences between sampling rates at different temperatures (range of 20 to 30 °C) and air velocities (2 to 50 cm/s). On the opposite, relative humidity (RH) had a significant effect on sampling rates. Method reproducibility was realized in the laboratory and field conditions and was 6.2 % and 7 to 11 %, respectively. Repeatability was also determined as 8.9 %. Comparison of the results according to the American Industrial Hygiene Association exposure assessment strategy showed the SPME sampler yields more conservative results in comparison with traditional standard method.