Abstract:
Linear solvation energy relationships (LSERs) are applied as classifiers to predict the logarithmic retention factors logk from the structures of candidate compounds in non-target analysis. By comparison of the predicted value with the experimentally determined logk, progressive exclusion of candidates is done. The approach is based on the determination of stationary phase parameters to describe ten different gas chromatographic columns under four isothermal conditions. To demonstrate retention prediction and the application of the classifier model, twelve compounds with the molecular formula C(12)H(10)O(2) were selected, while experimental logk values were compared to the predicted values and exclusion of potential candidate compounds was performed. The analytical power of the approach was demonstrated on the basis of experimentally determined compound descriptors achieved from gas chromatographic measurements. The prediction got less accurate when calculated compound descriptors were employed. For the time being insufficient precision in estimating the descriptors limits the possibility to exclude candidate compounds in non-target analysis. It is expected that new approaches to estimate compound descriptors, will improve this situation. At present, the insufficient accuracy of descriptor estimates can be dealt with larger prognosis intervals. Furthermore, the combination of two stationary phases with corresponding retention prediction further advanced the exclusion of potential candidates. The most appropriate pair of stationary phases was selected by the application of four different orthogonal strategies. In addition, the classifier was applied for a validation set with different molecular composition, where column selection was considered on the basis of the differences in the compound descriptors of the corresponding candidate compounds.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...