Related Experiment Video
Updated: May 17, 2026

Mechanical Ventilation Boot Camp Curriculum
Published on: March 12, 2018
Effect of feedback on ventilator care bundle compliance: before and after study
Petra Lawrence1, Paul Fulbrook
1Nursing Research and Practice and Development Centre, The Prince Charles Hospital, Brisbane, Queensland, Australia.
Monthly feedback on ventilator care bundle (VCB) compliance in intensive care units showed variable effects. While one unit improved significantly, the other saw declines, highlighting the need for further research on effective feedback strategies.
Area of Science:
- Critical Care Medicine
- Healthcare Quality Improvement
- Evidence-Based Practice Implementation
Background:
- Ventilator care bundles (VCB) are widely used in intensive care settings to standardize evidence-based practices.
- Ensuring consistent compliance with VCB elements is crucial for patient outcomes.
Purpose of the Study:
- To evaluate the impact of monthly performance feedback on adherence to the ventilator care bundle (VCB).
Main Methods:
- A before-and-after study design was employed in two metropolitan intensive care units.
- Ventilator care bundle compliance data were collected weekly over one year, with monthly feedback provided during the second six months.
Main Results:
- Overall compliance and 'all or nothing' compliance showed mixed results, increasing in one ICU (B) but decreasing in another (A).
- ICU B demonstrated a statistically significant increase in overall VCB compliance.
- Compliance with head of bed elevation remained a challenge, consistent with prior research.
Conclusions:
- The effectiveness of monthly feedback on VCB compliance is variable and requires further investigation.
- Additional research is necessary to identify optimal audit and feedback strategies for improving care bundle adherence.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: