J R Infante1, L García, P Laguna
1Servicio de Medicina Nuclear, Complejo Hospitalario Universitario de Badajoz, Badajoz, Spain. infantetorre@yahoo.com
Unlabelled:
Edema of the limbs is a common reason for medical consultation, for which the lymphoscintigraphy is considered to be a reliable method for its differential diagnosis.
Objective:
To evaluate the usefulness of radionuclide studies in the differential diagnosis of edema, and the diagnostic yield of different scintigraphic patterns.
Material And Methods:
A total of 61 patients, mean age 43 years, referred to our Department in the last three years for suspected lymphoedema, were considered. One patient was discarded due to lack of diagnosis, 56 had lower limb edema and 4 upper limb edema. After intradermal injection of two doses of (99m)Tc-nanocolloid, scintigraphic scans were made at 30 and 120minutes. The final diagnosis was based on imaging tests, clinical course, and response to treatment. We calculated the parameters of the diagnostic yield of four different scintigraphic patterns (presence of dermal backflow, asymmetry-alteration in inguinal/axillary nodes, presence of collateral pathways, and visualization of intermediate lymph nodes), considering them individually and jointly.
Results:
The best diagnostic yield was achieved by considering dermal backflow and asymmetry in inguinal/axillary nodes (accuracy 88.9%, specificity 96.4%, PPV 95.5%). Evaluation of intermediate lymph nodes and presence of collateral pathways contributed little to the diagnostic yield, showing poor sensitivity and high false positive rates.
Conclusion:
The lymphoscintigraphy had high diagnostic yield, allowing early treatment of lymphœdema. The dermal backflow and asymmetry in inguinal/axillary nodes had the greatest diagnostic accuracy. Evaluation of intermediate lymph nodes and visualization of collateral pathways contributed little to improving the diagnosis.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET