Related Experiment Video
Updated: May 17, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Compatibility of the repairable-conditionally repairable, multi-target and linear-quadratic models in converting
Hiromitsu Iwata1, Naruhiro Matsufuji, Toshiyuki Toshito
1Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi 467-8601, Japan. h-iwa-ncu@nifty.com
Abstract:
We investigated the applicability of the repairable-conditionally repairable (RCR) model and the multi-target (MT) model to dose conversion in high-dose-per-fraction radiotherapy in comparison with the linear-quadratic (LQ) model. Cell survival data of V79 and EMT6 single cells receiving single doses of 2-12 Gy or 2 or 3 fractions of 4 or 5 Gy each, and that of V79 spheroids receiving single doses of 5-26 Gy or 2-5 fractions of 5-12 Gy, were analyzed. Single and fractionated doses to actually reduce cell survival to the same level were determined by a colony assay. Single doses used in the experiments and surviving fractions at the doses were substituted into equations of the RCR, MT and LQ models in the calculation software Mathematica, and each parameter coefficient was computed. Thereafter, using the coefficients and the three models, equivalent single doses for the hypofractionated doses were calculated. They were then compared with actually-determined equivalent single doses for the hypofractionated doses. The equivalent single doses calculated using the RCR, MT and LQ models tended to be lower than the actually determined equivalent single doses. The LQ model seemed to fit relatively well at doses of 5 Gy or less. At 6 Gy or higher doses, the RCR and MT models seemed to be more reliable than the LQ model. In hypofractionated stereotactic radiotherapy, the LQ model should not be used, and conversion models incorporating the concept of the RCR or MT models, such as the generalized linear-quadratic models, appear to be more suitable.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Pharmacodynamic Models: Linear Concentration–Effect Model
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Multicompartment Models: Overview
These models offer a more comprehensive representation of drug behavior in the body than one-compartment models. They accommodate the complexity of drug distribution,...
Compartment Models: Single-Compartment Model