Related Experiment Video
Updated: May 17, 2026

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Reappraisal of classical electrocardiographic criteria in detecting accessory pathways with a strict para-Hisian
E González-Torrecilla1, R Peinado, J Almendral
1Cardiology Department, Hospital General Universitario Gregorio Marañón, Universidad Complutense de Madrid, Madrid, Spain. etorrecilla@telefonica.net
Background:
Identification of electrocardiographic (ECG) criteria for para-Hisian accessory pathways (APs) is based on a small series of patients. The presence of a negative delta wave in leads V(1) and V(2) has been suggested as an ECG marker of this AP location.
Objective:
To validate these ECG findings in a large series of patients with strict invasive criteria for that location.
Methods:
We included 105 patients (39 women, 66 men; mean age 26 ± 12 years, range 5-82 years) with an ECG pattern compatible with preexcitation through an anteroseptal or midseptal AP following established ECG criteria. A para-Hisian AP was defined when the location of its successful catheter ablation coincided with either the largest recordable His bundle electrogram or a His bundle potential of>0.1 mV. Patients without that definition were included in the control group.
Results:
A para-Hisian location of the AP was found in 52 patients. AP locations of the remaining 53 patients (control group) were anteroseptal (n = 39), midseptal (n = 9), and fasciculoventricular (n = 5). A negative delta wave in leads V(1) and V(2) was observed in 13 patients with para-Hisian APs (sensitivity 25%; specificity 92%). However, the sum of initial r-wave amplitudes in those leads was<0.5 mV in 44 of the patients with para-Hisian APs and in 13 patients of the control group (sensitivity 85%; specificity 75.5%; area under receiver-operator characteristic curve 0.85).
Conclusions:
The presence of negative delta waves in leads V(1) and V(2) indicates a poor sensitivity and high specificity to detect APs with a strict definition of para-Hisian location. The sum of initial r-wave amplitudes in those ECG leads could be a useful, adjunctive marker in the noninvasive identification of these challenging APs.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism, and...
Electrophysiology of Normal Cardiac Rhythm