Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure

Giacomo Pucci1, Joseph Cheriyan, Annette Hubsch

  • 1Clinical Pharmacology Unit, University of Cambridge & Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK. giacomo.pucci@gmail.com

Journal of Hypertension
|October 20, 2012
PubMed

Insights

The Vicorder device reliably estimates central blood pressure (cBP) when calibrated to invasive measurements. It offers a simple, noninvasive alternative to tonometry-based methods for assessing cBP.

Area of Science:

  • Cardiovascular physiology
  • Medical device technology
  • Hypertension research

Background:

  • Central blood pressure (cBP) is a crucial indicator of cardiovascular risk.
  • Accurate cBP measurement is essential for effective hypertension management.
  • Existing methods for cBP estimation have limitations.

Purpose of the Study:

  • To evaluate the accuracy of the Vicorder, a novel brachial cuff-based device, in estimating central blood pressure (cBP).
  • To compare the Vicorder's performance against the SphygmoCor device and invasive measurements.
  • To assess the impact of different calibration methods on cBP estimation accuracy.

Main Methods:

  • Simultaneous invasive cBP measurements were taken during cardiac angiography in 50 patients.
  • The Vicorder and SphygmoCor devices were used to estimate cBP in these patients.
  • A separate noninvasive study compared the two devices in 90 healthy individuals using different calibration techniques.

Main Results:

  • Both Vicorder and SphygmoCor met accuracy criteria when calibrated to invasive mean arterial pressure (MAP)/diastolic blood pressure (DBP).
  • Calibration using oscillometric brachial blood pressure led to underestimation of cSBP by both devices.
  • Vicorder demonstrated a good correlation with SphygmoCor in noninvasive settings when calibrated appropriately.

Conclusions:

  • The Vicorder provides reliable cSBP estimates when calibrated to invasive pressure, serving as a potential noninvasive alternative to tonometry.
  • Calibration method significantly impacts the accuracy of both Vicorder and SphygmoCor.
  • Further research may validate Vicorder's clinical utility in diverse populations.
Abstract

Related Concept Videos

Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.