Related Experiment Video
Updated: Jan 30, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Analysis of 30 synthetic cannabinoids in oral fluid using liquid chromatography-electrospray ionization tandem mass
Stefan Kneisel1, Volker Auwärter, Jürgen Kempf
1Institute of Forensic Medicine, University Medical Center Freiburg, Albertstr. 9, 79104, Freiburg, Germany.
Abstract:
In recent years, the analysis of synthetic cannabinoids in human specimens has gained enormous importance in the broad field of drug testing. Nevertheless, the considerable structural diversity among synthetic cannabinoids already identified in 'herbal mixtures' hampers the development of comprehensive analytical methods. As the identification of the main metabolites of newly appearing substances is very laborious and time-consuming, the detection of the parent compounds in blood samples is the current approach of choice for drug abstinence testing. Whenever blood sampling is not possible however, the need for alternative matrices arises. In this article, we present a fully validated liquid chromatography-electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the analysis of 30 synthetic cannabinoids in oral fluid samples collected with the Dräger DCD 5000 collection device. The method proved to be suitable for the quantification of 28 substances. The limits of detection were in the range from 0.015 to 0.9 ng/ml, while the lower limits of quantification ranged from 0.15 to 3.0 ng/ml. The method was successfully applied to 264 authentic samples during routine analysis. A total of 31 samples (12%) was tested positive for at least one of the following synthetic cannabinoids: AM-694, AM-2201, JWH-018, JWH-019, JWH-081, JWH-122, JWH-203, JWH-210, JWH-250, JWH-307, MAM-2201, and RCS-4. Given that stabilization of the collection pads after sampling is warranted, the collection device provides satisfactory sensitivity. Hence, whenever blood sampling is not possible, the Dräger DCD 5000 collection device offers a good tool for the analysis of synthetic cannabinoids in oral fluid in the broad field of drug testing.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Tandem Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...