A 3D Quantification Technique for Liver Fat Fraction Distribution Analysis Using Dixon Magnetic Resonance Imaging
Published on: October 20, 2023
[Modified DIXON: examination of the different flip angles and echo times for water-fat separation and contrast]
Yasuo Takatsu1, Takayuki Nakatsuka, Tosiaki Miyati
1Department of Radiology, Osaka Red Cross Hospital.
Abstract:
The method known as DIXON is imaging from two different echo times (TE), using the opposite phase of water and fat. Modified DIXON (mDIXON) is the method that is calculated from changing the opposing phases 'in' and 'opposed' phases of the actual measurement, to fit the theoretical value. We reviewed that the effect of the water-fat separation and contrast depended on the different flip angles (FA) and echo times (TE). The diluted gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) (from 0 to 5 mmol/l) and liver model was stabilized by lard. In order to measure the SNR and %CV of the lard, the various combinations of TE and FA (from 5 to 20 degrees) were changed. The suitable range for the measurement of the SNR and %CV of the lard, and the contrast of gadolinium Gd-EOB-DTPA and the liver model, in the axial view (including 50% fat), was around the 'opposed' phase in the first TE (TE1) and around the 'in' phase in the second TE (TE2) and FA: 15degrees (TE1: 2.0-2.9 ms, TE2: 4.1-5.0 ms). In order to avoid phase dispersion, shorter TE range is more desirable (TE1: 2.0-2.25 ms, TE2: 4.1-4.5 ms). It is our understanding that the water-fat separation is better in these ranges and under these circumstances, good contrast was obtained.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies II: Ultrasonography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...