Related Experiment Video
Updated: May 17, 2026

Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Complete transmural gastric migration of PTFE mesh after surgery for a recurrent hiatal hernia
V Porziella1, A Cesario, F Lococo
1Department of Thoracic Surgery, Catholic University of Sacred Heart, Rome, Italy. vporziella@rm.unicatt.it
Abstract:
Complications directly associated with the use of prosthetic materials in large hiatal hernia repair are rarely cited events in the literature. We herein report a case of a 47 year-old woman who came to our attention for a subacute onset of severe dysphagia and weight loss. She previously underwent laparotomic Nissen fundoplication with PTFE dual-mesh cruroplasty for a large recurrent hiatal hernia. With the clinical suspicious of "Tight Nissen", an endoscopy was performed and revealed a circular stenosis in the lower esophagus, a rotation of the stomach and, surprisingly, the presence of PTFE mesh free-moving in the gastric lumen With the use of rattooth forceps, the foreign body was removed and, after few days, the patient underwent a surgical debridement of hiatal scar tissue and a gastropexy procedure. In conclusion, dysphagia may manifest during the early postoperative period after mesh repair antireflux surgery, but such dysphagia usually resolves; if it doesn't or if it worsens, mesh migration must be excluded.
Related Concept Videos
Hiatal Hernia
Peptic Ulcer Disease V: Surgical Management and Nursing Care
Surgical Interventions for Peptic Ulcer Disease
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations: