J M Groen1, K F Kofoed, M Zacho
1Department of Radiology, University of Groningen, University Medical Center Groningen, The Netherlands. jaap.groen@slaz.nl
Introduction:
Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which enables establishment of a calcium scoring protocol for MDCT that yields a calcium score comparable to the EBT values and to the physical mass.
Materials And Methods:
A phantom containing 100 small calcifications ranging from 0.5 to 2.0mm was scanned on EBT using a standard coronary calcium protocol. In addition, the phantom was scanned on a 320-row MDCT scanner using different scanning, reconstruction and scoring parameters (tube voltage 80-135 kV, slice thickness 0.5-3.0mm, reconstruction kernel FC11-FC15 and threshold 110-150 HU). The Agatston and mass score of both modalities was compared and the influence of the parameters was assessed.
Results:
On EBT the Agatston and mass scores were between 0 and 20, and 0 and 3mg, respectively. On MDCT the Agatston and mass scores were between 0 and 20, and 0 and 4 mg, respectively. All parameters showed an influence on the calcium score. The Agatston score on MDCT differed 52% between the 80 and 135kV, 65% between 0.5 and 3.0mm and 48% between FC11 and FC15. More calcifications were detected with a lower tube voltage, a smaller slice thickness, a sharper kernel and a lower threshold. Based on these observations an acquisition protocol with a tube voltage of 100 kV and two reconstructions protocols were defined with a FC12 reconstruction kernel; one with a slice thickness of 3.0mm and a one with a slice thickness of 0.5mm. This protocol yielded an Agatston score as close to the EBT as possible, but also a mass score as close to the physical phantom value as possible, respectively.
Conclusion:
With the new phantom one acquisition protocol and two reconstruction protocols can be defined which produces Agatston scores comparable to EBT values and to the physical mass.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Acute Coronary Syndrome III: Diagnostic Studies