Interobserver variability among radiologists for diagnosis of scaphoid fractures by computed tomography
Andele D de Zwart1, Frank J P Beeres, Lucas M Kingma
1Department of Surgery, Landsteiner Institute, Medical Centre Haaglanden, The Hague. A.D.de_Zwart@lumc.nl
Purpose:
To determine the interobserver variability among radiologists for computed tomography (CT) diagnosis of scaphoid fractures.
Methods:
Four specialized musculoskeletal radiologists evaluated the CT scans of 150 consecutive patients who were clinically suspected of having sustained a scaphoid fracture but whose scaphoid-specific radiographs were normal. The radiologists were asked to determine the presence or absence of a scaphoid fracture and to localize the fracture. Interobserver agreement was calculated using the kappa statistic.
Results:
The radiologists diagnosed between 11 (7%) and 22 (15%) scaphoid fractures; the kappa value was 0.51.
Conclusion:
Agreement on the presence of a scaphoid fracture and its location on a CT scan was moderate among the 4 radiologists. This finding raises the question as to whether scaphoid fractures could be under- or overdiagnosed in daily practice when CT is used to exclude or confirm a fracture. This should be kept in mind when interpreting clinical and radiological results in patients with suspected scaphoid fractures.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
06:31Erosion Identification in Metacarpophalangeal Joints in Rheumatoid Arthritis using High-Resolution Peripheral Quantitative Computed Tomography
Published on: October 6, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...