Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
System design for integrated comprehensive and multidimensional gas chromatography with mass spectrometry and
Sung-Tong Chin1, Graham T Eyres, Philip J Marriott
1Centre for Green Chemistry, School of Chemistry, Monash University, Wellington Road, Clayton, VIC 3800, Australia.
Abstract:
An integrated system having the combined capability to perform gas chromatography (GC), comprehensive two-dimensional GC (GC × GC), and target heart-cut multidimensional GC (MDGC) using olfactometry (O), flame ionization (FID), and/or mass spectrometry (MS) detection is described. This combines a number of contemporary GC methods into a single instrument to provide very high resolution profiling of a sample. This provides initial assessment of volatile compound composition through GC × GC analysis with FID, which can be correlated with GC analysis using parallel O and FID detection. Subsequent microfluidic (Deans) switching selects regions (heart-cuts) of the chromatographic elution from the first dimension ((1)D) column for further resolution on a long second dimension ((2)D(L)) column for parallel detection of O and MS. Various (2)D(L) operational conditions, as well as the effect of different heart-cut (H/C) duration, were compared. The favored mode involves cryotrapping of heart-cuts, cooling the oven, and reducing carrier flow to offer greater efficiency. An analytical strategy that incorporates GC-FID/O, GC × GC-FID, and MDGC-MS/O analyses with cumulative solid phase microextraction (SPME) sampling for volatile sample enrichment is presented in this work. Excellent qualitative and quantitative performance was demonstrated with a Shiraz wine sample and an allergens mixture, with tentative identification of acetic acid, octen-3-ol, and ethyl octanoate as aroma contributors in Shiraz wine and determination of β-damascenone (floral odor) well separated from hexanoic acid (sweaty odor). A novel approach to obtain (2)D retention indices is reported, allowing matching of mass spectral, (1)I (retention index in (1)D) and (2)I (retention index in (2)D) data. The method employs the same olfactory detector at the end of the (1)D and (2)D(L) columns.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...