Related Experiment Video
Updated: May 17, 2026

Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
Could the eZ-SCOPE AN gamma camera replace intraoperative measurement of iPTH for PHPT?
Takaaki Fujii1, Reina Yajima, Satoru Yamaguchi
1Department of General Surgical Science, Graduate School of Medicine, Gunma University, Gunma, Japan. ftakaaki@med.gunma-u.ac.jp
Abstract:
Intraoperative intact parathyroid hormone (iPTH) measurements have been proposed as an effective assay in surgery for primary hyperparathyroidism (PHPT). We have demonstrated the efficiency of the use of a hand-held gamma camera, eZ-SCOPE AN, with technetium-99m sestamibi (Tc-MIBI) scintigraphy for navigation surgery for PHPT. The aim of this preliminary study was to assess the possibility that the eZ-SCOPE AN can replace the measurement of intraoperative iPTH in surgery for PHPT. Sixteen consecutive patients with documented primary hyperparathyroidism underwent surgery using this compact camera. iPTH was routinely measured preoperatively and 10 minutes after the complete removal of adenoma. All patients had a well-defined parathyroid lesion identified on preoperative Tc-MIBI. The eZ-SCOPE revealed hyperfunctioning parathyroid glands in all cases. iPTH levels were decreased in all cases after the removal of adenomas. Our results suggest that this gamma camera is useful for confirming complete resection of endocrinologically active tissue in surgery for PHPT. In selective patients with scan-positive cases identified by preoperative Tc-MIBI, the eZ-SCOPE may replace the intraoperative iPTH assay in surgery for PHPT.
More Related Videos
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
06:55Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...