Background:
Two previous studies recently raised the possibility of a high risk of early femoral components loosening with high-flexion (HF) prostheses in Asian populations and suggested that the high failure rate of HF TKAs was associated with HF ability. However, these findings are controversial given other studies reporting a low incidence of aseptic failures in HF prostheses.
Questions/Purposes:
We therefore determined (1) the rate of achieving postoperative HF after HF TKA; (2) whether the aseptic loosening rate of HF prostheses is high; and (3) whether the survivorship was worsened in patients who achieved postoperative deep knee flexion in our cohort of Korean patients.
Methods:
We retrospectively reviewed 488 patients who had 698 primary TKAs using the NexGen(®) Legacy Posterior-Stabilized Flex system implanted from 2003 to 2010. There were 40 men and 448 women with a mean age of 68 years. We obtained Hospital for Special Surgery scores, maximal flexion, and radiographs. The minimum followup for functional and radiographic evaluations was 2 years (median, 4.8 years; range, 2-8.7 years). We performed a survival analysis on all patients for aseptic loosening.
Results:
Three hundred sixty knees (52%) could achieve ≥ 135° maximum flexion. Six of the 698 knees (0.9%) developed aseptic loosening (three femoral and three tibial). The survival at 5 years for aseptic loosening was 99.1%. The overall survival for aseptic failure did not differ between knees that achieved HF and those that did not.
Conclusions:
We observed a low incidence of early aseptic loosening of HF designs in this series. Our findings suggest HF TKAs have high survival in Asian patients at 5 years although half of the patients attained maximum flexion more than 135° postoperatively.