Related Experiment Video
Updated: May 17, 2026

A Practical and Novel Method to Extract Genomic DNA from Blood Collection Kits for Plasma Protein Preservation
Published on: May 18, 2013
Influence of method of specimen collection on various preanalytical sample quality indicators in EDTA blood collected
Tester F Ashavaid1, Sucheta P Dandekar, S Khodaiji
1Department of Laboratory Medicine, P.D. Hinduja National Hospital & Medical Research Center, Mahim, Mumbai, 400016 India ; Department of Laboratory Medicine, P. D. Hinduja National Hospital & Medical Research Centre, Veer Savarkar Marg, Mahim, Mumbai, 400 016 India.
Abstract:
Improving specimen quality as well as healthcare worker (HCW) safety poses significant concerns for today's laboratories. With an increasing number of diagnostic tests requested, laboratory professionals are faced with challenges to reduce laboratory errors, improve the quality of laboratory results to assure accurate diagnosis and implement initiatives to ensure healthcare worker safety and minimize risk of exposure to bloodborne pathogens. A prior study conducted in 2008 reported that variations in blood collection methods for clinical chemistry assays may affect overall specimen quality. As a follow up, the current study assessed the quality of 22563 patient specimens for cell counting in EDTA blood collection tubes that were obtained with needle and syringe collection (open) using either disposable tubes or re-washed glass vials or with an evacuated blood collection system (closed). Based on the observations, the use of the evacuated blood collection system resulted in better preanalytical specimen quality as compared with needle and syringe collection. The findings also showed an approximately 70-fold reduction in the incidence of clotting as well as fewer instrument-generated flags using the evacuated collection system. In addition, the use of an evacuated collection system for venous blood collection demonstrated lesser chance of blood exposure to healthcare workers.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration
Complexometric EDTA Titration Curves
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
EDTA: Auxiliary Complexing Reagents