Related Experiment Video
Updated: May 17, 2026

Detection of Glycosaminoglycans by Polyacrylamide Gel Electrophoresis and Silver Staining
Published on: February 25, 2021
Capillary electrophoresis of heparin and other glycosaminoglycans using a polyamine running electrolyte
Thomas N Loegel1, John D Trombley, Richard T Taylor
1Department of Chemistry and Biochemistry, Miami University, Oxford, United States.
Abstract:
This study involves the use of polyamines as potential resolving agents for the capillary electrophoresis (CE) of glycosaminoglycans (GAGs), specifically heparin, dermatan sulfate, chondroitin sulfate, over-sulfated chondroitin sulfate (OSCS), and hyaluronan. All of the compounds can be separated from each other with the exception of chondroitin sulfate and hyaluronan. Using optimization software, the final run conditions are found to be 200 mM ethylenediamine and 45.5 mM phosphate as the electrolyte with -14 V applied across a 50 μm ID×24.5 cm fused silica capillary at 15°C. The ion migration order, with OSCS as the last instead of the first peak, is in contrast to previous reports using either a high molarity TRIS or lithium phosphate run buffer with narrower bore capillaries. Total analysis time is 12. 5 min and the relative standard deviation of the heparin migration time is about 2.5% (n=5). The interaction mechanism between selected polyamines and heparin is explored using conductivity measurements in addition to CE experiments to show that an ion-pairing mechanism is likely.
More Related Videos
04:36Rapid Separation and Display of Active Fibrinogenolytic Agents in Sipunculus nudus through Fibrinogen-Polyacrylamide Gel Electrophoresis
Published on: April 19, 2024
12:34Two-dimensional Gel Electrophoresis Coupled with Mass Spectrometry Methods for an Analysis of Human Pituitary Adenoma Tissue Proteome
Published on: April 2, 2018
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Capillary Electrophoresis: Instrumentation