Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Wrist-worn accelerometers in assessment of energy expenditure during intensive training
H Kinnunen1, M Tanskanen, H Kyröläinen
1Polar Electro Oy, Kempele, Finland. hannu.kinnunen@polar.fi
Abstract:
We assessed the ability of the Polar activity recorder (AR) to measure energy expenditure (EE) during military training. Twenty-four voluntary male conscripts participated in the study and wore an AR on the non-dominant wrist 24 h a day for 7 d. The AR analyzed and stored the frequency of hand movements (f_hand) into memory at 1 min intervals. The relationship between f_hand and EE was studied over a 7 d period of military training using the doubly labeled water (DLW) technique. In addition, the relationship between f_hand and EE was analyzed during walking and running on a treadmill with an indirect calorimeter (IC), and f_hand was measured during a supervised 45 min field march test where the conscripts carried combat gear. EE was expressed as physical activity level (PAL), total energy expenditure (TEE), and activity-induced energy expenditure adjusted for body mass (AEE/BM). Over the 7 d period, f_hand alone explained 46% of inter-individual variation in PAL(DLW). After inclusion of body height and mass in the model used to predict PAL(DLW) from f_hand, a very high positive correlation and a low standard error of estimate (SEE) were observed between the AR and DLW techniques: for TEE r = 0.86 (p < 0.001), the SEE was 6.3%, and for AEE/BM r = 0.84 (p < 0.001), the SEE was 12.8%. In the treadmill exercise, f_hand correlated highly with PAL(IC) (r = 0.97 ± 0.02). In the 45 min field march test, the AR measured similar f_hand as on the treadmill at the same speed. In conclusion, the wrist-worn AR can be regarded as a reliable and valid method for assessing EE during intensive training.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: