Related Experiment Video
Updated: May 17, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Variations in exhaled nitric oxide concentration after three types of dives
Pieter-Jan van Ooij1, Antoinette Houtkooper, Rob van Hulst
1Senior diving medicine physician at the Diving Medical Centre, Royal Netherlands Navy, PO Box 10.000 1780 CA Den Helder, The Netherlands, Phone: +31-(0)223-653076, Fax: +31-(0)223-653148,
Introduction:
An increase in exhaled nitric oxide concentration (FENO) occurs during an exacerbation of chronic obstructive lung disease or other inflammatory processes of the airway. Raised FENO levels are also observed during normobaric, mild hyperoxic exposures, whereas after hyperbaric hyperoxic exposure the FENO level is reduced. This study investigated the variations of FENO after three different types of dives.
Methods:
Military divers participated in either a closed circuit rebreather dive (CCR, n = 17, pO2 = 130 kPa), semi-closed circuit rebreather dive (S-CCR, n = 12, pO2 = 180 kPa) or a compressed air dive (scuba, n = 17 pO2 = 126 or attendant, n = 12, pO2 = 118). Before and after each dive, the FENO was measured using a handheld electrochemical analyser (Niox Mino®).
Results:
All values for FENO feel within the normal range (5-25ppb). A small decrease in FENO level was found after all dives. After CCR dives FENO fell from 16.4 (± 8.0) pre-dive to13.6 (± 7.5) ppb, S-CCR from 16.2 (± 7.2) to 13.6 (± 6.3) ppb, scuba from 17.1 (± 5.6) to 16.1 (± 5.2) ppb and attendants from 17.7 (± 9.8) to 17.3 (± 9.1) ppb. Only after a CCR or S-CCR dive was this decrease statistically significant (P < 0.05).
Conclusion:
In our divers, hyperbaric hyperoxia up to 180 kPa led to a small decrease in FENO in the conductive compartment of the lungs, the biological importance of which is unknown.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Factors Affecting Respiration

